Info |
---|
TIP: Use a keyboard shortcut key to find eCQM Warning & Error Messages help content by number. “Control” + “F” for Windows |
Table of Contents:
...
Purpose:
...
Data Accuracy / Source Viewer Messages for Data Edits and Schematron Rules
Data Accuracy Messages
...
Event start date after the end date (error)
...
Event start date after the end date (warning)
...
Inpatient encounter outside of the reporting quarter (warning)
...
Inconsistent reporting of Inpatient Encounter (warning)
...
Duplicate Inpatient Encounter Detected (warning)
...
Incorrect CCN Reported (error)
...
Invalid DateTime (error/warning)
...
Invalid Patient ID (error)
...
Invalid QRDA XML file (error)
...
None of the measures supported by TJC (error)
...
Missing or Invalid Admission Date (error)
...
Missing or Invalid Discharge Date (error)
...
Missing or Invalid Header EffectiveTime (error)
...
No Discharge Date in Reporting Period (error)
...
r-validate_TZ-errors (error)
...
QDM_based_QRDA_V7-TJC-errors (error)
...
A required Medication Route is missing (warning)
...
Unacceptable Unit Reported (warning)
...
r-DOCUMENT-TJC-QDM-HEADER-warnings (warning)
...
r-DOCUMENT-TJC-QRDA-HEADER-warnings (warning)
...
r-DOCUMENT-TJC-US-HEADER-warnings (warning)
...
Reporting-Parameters-Act-TJC-errors (error)
...
Table of Contents:
Purpose
The difference between Error & Warning Messages
Data Accuracy / Source Viewer Messages for Data Edits and Schematron Rules
Data Accuracy / Source Viewer Error & Warning Messages
Schematron Error & Warning Messages
Purpose:
Below are The Joint Commission specific error and warning messages generated by the edits and Schematron rules executed against each uploaded QRDA I Document. In addition, those CMS and Health Level Seven (HL7) Schematron rules that are frequently encountered when data is uploaded to the DDS Platform are also included below.
...
QRDA I documents that generate one or more error messages have been rejected and not processed against the eCQM logic. They are available for you to view within the Source Viewer from the Data Accuracy page. Since they have not been processed against the eCQM logic, they are not available on the Quality Improvement page and cannot be submitted via the Submit Data page.
QRDA I documents that generated one or more warning messages AND no error messages may be submitted. We recommend that hospitals review the warning messages to ensure they are not pointing to issues with data capture, data mapping, or QRDA I file generation that can be corrected before the submission deadline. However, we do realize that hospitals may not have the ability to regenerate QRDA I documents from prior years and so they are unable to correct these warning messages. If this is your situation, we suggest you continue to review the warning messages and, if needed, work to update your software for the next calendar year and for future years so as to eliminate these warning messages to ensure your measure rates are as accurate as possible.
...
For more information concerning CMS or HL7 Conformance numbers, see the below reference material:
CMS: Visit For the documents associated with this year’s data, visit the eCQI Resource Center CMS QRDA IG publication page for the documents associated to this year's data, or copy and paste the following web address in your internet browser: https://ecqi.healthit.gov/qrda-quality-reporting-document-architecture.
HL7: Visit For the documents applicable for this year’s data, visit the HL7 website to obtain the version of the HL7 CDA® R2 IG: QRDA I applicable for this year's data, or copy and paste the following web address in your internet browser: http://www.hl7.org/implement/standards/product_brief.cfm?product_id=35.
The HL7 website may require a HL7 account in order to download the Implementation Guide (IG).
The HL7 website header states the current Release number. Scroll to the bottom of the page to find the Release that is appropriate for this calendar years data.
See the eCQM Version Alignment with CMS documentation for information concerning the version of measures, CMS QRDA IG, and HL7 standards that are applicable to this year's data.
Data Accuracy Messages
...
title | Event start date after the end date (error) |
---|
...
.
...
Section / Element: High@value
All Event End Dates (@high) used by the eCQMs must be before the associated Event Start Date (@low).
Apply offset before validation.
Expand | ||
---|---|---|
| ||
|
Expand | ||
---|---|---|
| ||
|
...
title | Inconsistent reporting of Inpatient Encounter (warning) |
---|
...
Section / Element: Encounter ID
When two or more inpatient encounters exist, they are processed as the same encounter if there:
admit and discharge dates are the same or
encounter IDs and extension are the same
If the same inpatient encounters are reported, only the valueset may be different. Everything else should be the same. This edit is triggered if any of the below conditions exist:
admit or discharge date is different
encounter ID or extension is different
encounter code/codeSystem is different
...
title | Duplicate Inpatient Encounter Detected (warning) |
---|
...
Section / Element: Encounter ID
Admit and discharge dates, encounter code and encounter ID (root and extension) are the same among duplicates.
Expand | ||
---|---|---|
| ||
Note: We have not built the functionality to receive a file containing solely our HCO ID due to our desire to reduce hospital costs and other burden. By receiving the file using CMS' CCN, it allows hospitals to submit the same QRDA I document that they submit to CMS to The Joint Commission. The CCN on file within the DDS Platform has been taken from your organization’s accreditation application - so it is possible it also needs to be updated there as well. |
...
title | Invalid DateTime (error) |
---|
The 'Invalid DateTime’ error is associated to two Source Viewer messages:
...
Data Accuracy / Source Viewer Error Messages
Anchor | ||||
---|---|---|---|---|
|
Info |
---|
Table is in order by Message # |
TIP: Use Keyboard shortcut to find specific numerical or text strings in the table below, i.e.
“Control” + “F” for Windows
”Command-F” for MAC
...
Message # | Section/ Element | Status | Data Accuracy Label | Source Viewer Description | Expected Behavior in Source Viewer Upon Clicking Error | Additional Information |
100001 | Discharge Date | Critical | Missing Encounter Performed Relevant Period High Date | Encounter Performed Relevant Period High Date (effectiveTime/ high) is missing (TJC-100001) | Highlight the encounter performed section, which is missing the 'high' time field, in the source viewer | Validate effective-time 'high' field of all Encounter Performed which includes Inpatient encounter, ED, Observation. |
100002 | Discharge Date | Critical | Invalid Encounter Performed Relevant Period High Date | Invalid Encounter Performed Relevant Period High Date (effectiveTime/ high) has been provided or it's before 1900. (TJC-100002) | Highlight the encounter performed section which has invalid 'high' time in the source viewer | Apply all date validation |
100004 | Discharge Date | Critical | Invalid Encounter Performed Relevant Period High Date | Encounter Performed Relevant Period High Date (effectiveTime/ high) must be precise to the minute. (TJC-100004) | Highlight the encounter performed section which has invalid 'high' time in the source viewer | Validate effective-time 'high' value of all Encounter Performed which includes Inpatient encounter, ED, Observation. |
100005 | Discharge Date | Critical | Encounter Performed Relevant Period High Date is out of range | Encounter Performed Relevant Period High Date effectiveTime/ high) cannot be greater than current date. (TJC-100005) | Highlight the encounter performed section which has invalid 'high' time in the source viewer | Validate effective-time 'high' value of all Encounter Performed which includes Inpatient encounter, ED, Observation. |
100006 | Admit Date | Critical | Invalid Encounter Performed Relevant Period Low Date | Invalid Encounter Performed Relevant Period Low Date effectiveTime/ low) has been provided or it's before 1900. (TJC-100006) | Highlight the encounter performed section, which has invalid the 'low' time field, in the source viewer | Apply all date validation |
100007 | Admit Date | Critical | Missing Encounter Performed Relevant Period Low Date | Encounter Performed Relevant Period Low Date effectiveTime/ low) is required. (TJC-100007) | Highlight the encounter performed section, which is missing the 'low' time field, in the source viewer | Validate effective-time 'low' field of all Encounter Performed which includes Inpatient encounter, ED, Observation. |
100008 | DateTime | Critical | Invalid DateTime | Invalid DateTime has been provided. (TJC-100008) |
...
Section / Element: DateTime
Highlight the template/EffectiveTime with incorrect date | Only validate effectiveTime, Time, and birthTime |
...
in QRDA that are listed in TJC xPath Document required by current eCQMs and other than Inpatient Encounter Performed Admit and discharge date.Check effectiveTime/Time/birthTime's provided values for accurate format.Validation for Assessment Performed Result as DateTime. |
...
|
...
o Section / Element: Result Unit
· This warning will only trigger when incorrect/invalid unit is provided for eCQM measure logic evaluation.
· Below are required unit as per CY2021 eCQM-
· 1) eSTK-6 - 'mg/dL' for Laboratory Test Performed
· 2) ePC-01, ePC-02, ePC-05, ePC-06 - 'wk', 'week' or 'weeks' for Assessment Performed Gestational Age calculation.
· 3) ePC-05, ePC-06 - 'g' for Assessment Performed Birth Weight calculation.
...
title | r-DOCUMENT-TJC-QDM-HEADER-warnings (warning) |
---|
· Source Viewer: This document SHALL contain exactly one [1..1] QDM-based QRDA document level templateId @root="2.16.840.1.113883.10.20.24.1.2" @extension="2019-12-01". QDM data elements will not be validated properly (TJC-050).
o Section / Element: Document Level templateID
...
- range 0-59 |
...
UUUU - UTC time shift -1300 thru+1400
...
Source Viewer: Invalid DateTime has been provided. (TJC-100012)
Section / Element: DateTime
The Joint Commission validates all the date/time fields that may NOT be used in measure evaluation.
Dates are evaluated for:
One or more part of dateTime field is not in the YYYYMMDDHHMMSSxUUUU format
Year must be in the range of 1900 to 9999
Month cannot be 00 or greater than 12
Day cannot be 00 and cannot be greater than 31
Day cannot exceed limit for month (Leap year calculation is validated)
Time formats in effectiveTime, time or birthTime elements (XML tags) are evaluated for:
One or more part of the Time field is not in one of these formats: HH, HHMM, HHMMSS, HHMMxUUUU, or HHMMSSxUUUU
HH may be between 00-23
MM may be between 00-59
SS may be between 00-59
xUUUU represents the UTC time shift and may be between -1300 thru +1400
x - plus or minus sign for the UTC time shift
UUUU - UTC time shift
Note: We have determined that some vendors are defaulting values into date/time fields instead of submitting a ‘null’ value or Nullflavor when something did not occur. Please refer to the Nullflavor discussion within CMS' Implementation Guide for QRDA I documents for an understanding of how missing or null datetimes should be submitted.
Two examples which trigger this rejection:
<effectiveTime xsi:type= "IVL_TS" >
<low value= "00010101000000" /> → the start date/time is defaulted as "00010101000000-0000"
</effectiveTime>
<effectiveTime xsi:type= "IVL_TS" >
<low value= "00" /> → the start time is defaulted as "00"
<high nullFlavor= "NI" />
</effectiveTime>
Expand | ||
---|---|---|
| ||
|
Expand | ||
---|---|---|
| ||
Invalid QRDA I Documents typically cannot be displayed within the Source Viewer and it may appear as a preprocess validation error on the Data Accuracy bar chart. (TJC-100031 and TJC-100027) There are two primary reasons for why the ‘Invalid QRDA XML file’ error is generated:
|
Expand | ||
---|---|---|
| ||
|
Expand | ||
---|---|---|
| ||
|
Expand | ||
---|---|---|
| ||
Note: At this time, The Joint Commission only utilizes inpatient measures. Therefore, all QRDA I Documents are expected to contain a valid Inpatient Encounter with a valid Discharge Date. Outpatient data (e.g., ED-3) will be rejected. |
Expand | ||
---|---|---|
| ||
|
Expand | ||
---|---|---|
| ||
· Source Viewer: There is no Inpatient Discharge Date within the reporting period in the QRDA file. (TJC-100022) o Section / Element: Discharge Date o This error is stating that the QRDA I document does not contain a Discharge Date or that the Discharge Date is not within the Reporting Period stated within the QRDA I document (i.e., calendar quarter). Discharge Date must be equal to or before 23:59:59 local time on the final day of the calendar quarter (reporting period). § Inpatient QRDA I documents rejected by this message need to be corrected by adding or updating the Discharge Date. Once corrected, the QRDA I document needs to be re-uploaded to the DDS Platform. § Outpatient QRDA I documents will not contain an inpatient Discharge Date. § Given that we have asked for the same zip files which were submitted to CMS to be submit to the DDS Platform, it is appropriate for these outpatient cases to be submitted since CMS will evaluate them against their ED-3 eCQM. § At the same time, it is correct for the DDS Platform to reject the outpatient cases since we do not utilize this measure. You can ignore the outpatient cases when submitting your hospital’s data. § When using the Submit Data page, you are only submitting the QRDA I document associated to the measures that you select to submit. Since ED-3 is not an option, the outpatient cases will remain solely within your hospital’s DDSP Workspace and will not be submitted to The Joint Commission. |
Expand | ||
---|---|---|
| ||
· Source Viewer: Inconsistent usage of time zone is found in the file. Time zone must be used (OR not used) consistently throughout the file in all Datetime fields which contain time part. (TJC-0043) o Section / Element: Time zone o Time Zone must be consistently either be included or not be included for all Date elements that include a time stamp (HH, HHMM, or HHMMSS). |
Expand | ||
---|---|---|
| ||
· Source Viewer: CCN (Facility CMS Certification Number), SHALL be six to ten characters in length (CONF:TJC-0011) o Section / Element: CCN o The hospital's Facility CMS Certification Number SHALL be six to ten characters in length. o The Joint Commission processes all data submitted to the DDS Platform based upon the hospital's CMS CCN, not the hospital's Joint Commission HCO ID. The Platform crosswalks the CCN back to the HCO ID for data storage and analysis purposes. § You can determine the CCN which The Joint Commission has linked to your HCO ID by going into HCO Characteristics (available from the main menu). If the CCN is incorrect, please complete the Support Ticket to inform us what the correct CCN should be and we will investigate. § Note: We have not built the functionality to receive a file containing solely our HCO ID due to our desire to reduce hospital costs and other burden. By receiving the file using CMS' CCN, it allows hospitals to submit the same QRDA I documents that they submit to CMS to The Joint Commission. The CCN on file within the DDS Platform has been taken from your organization’s accreditation application - so it is possible it also needs to be updated there as well. |
Expand | ||
---|---|---|
| ||
· Source Viewer: Route code is missing for an administered medication, and is required by a reported eCQM. (TJC-100037) o Section / Element: Route Code o This warning indicates that a Medication Template in the QRDA file should have the medication Route information because: § the QRDA I document denotes that it should be processed against VTE-1 or VTE-2 § the medication belongs to one of the below value sets used by VTE-1 or VTE-2 § the Route Code has not been negated with negationID=true. o The two Medication value sets for eVTE-1 and eVTE-2 require the Route Code: § "Medication, Administered: Unfractionated Heparin" using "Unfractionated Heparin RXNORM Value Set (2.16.840.1.113883.3.117.1.7.1.218)" with Attribute: "Route: Intravenous route" using "Intravenous route SNOMEDCT Value Set (2.16.840.1.113883.3.117.1.7.1.222)" § Medication, Administered: Low Dose Unfractionated Heparin for VTE Prophylaxis" using "Low Dose Unfractionated Heparin for VTE Prophylaxis RXNORM Value Set (2.16.840.1.113762.1.4.1045.39)" with Attribute:"Route: Subcutaneous route" using "Subcutaneous route SNOMEDCT Value Set (2.16.840.1.113883.3.117.1.7.1.223) o If you have not received the expected measure results for eVTE-1 or eVTE-2, you may update the QRDA I documents by adding the Route information, if available within the patient’s EHR, and regenerating the QRDA I documents (see below for more info). We then recommend that you Purge your data and upload the new zip file(s). To find the missing Route information: § In Data Accuracy tab, click on the magnifier next to the file name and it opens the Source Viewer. § Click on this message in the Source Viewer and the tool will take you to the correct template that is missing the <route>. § Compare your template with the example template from QRDA I Guide provided below. o Following is an example provided in HL7’s QRDA I Implementation Guide and you can see how the route is provided. Also, as given in the message description, if the <route> tag is provided, the code MUST be from value set OID=2.16.840.113883.3.88.12.3221.8.7, otherwise the document will receive an error message and will be rejected. § HL7 Example - Figure 67: Medication Activity (V2): |
...
title | Unacceptable Unit Reported (warning) |
---|
| ||||||
100009 | Admit Date | Critical | Invalid Encounter Performed Relevant Period Low Date | Encounter Performed Relevant Period Low Date effectiveTime/ low) value must be precise to the minute. (TJC-100009) | Highlight the encounter performed section, which has invalid the 'low' time field, in the source viewer | Validate effective-time 'low' value of Encounter Performed which includes Inpatient encounter, ED, Observation. |
100010 | Admit Date | Critical | Encounter Performed Relevant Period Low Date is out of range | Encounter Performed Relevant Period Low Date effectiveTime/ low) cannot be greater than current date (TJC-100010) | Highlight the encounter performed | Validate effective-time 'low' value of all Encounter Performed which includes Inpatient encounter, ED, Observation. |
100012 | DateTime | Warning | Invalid DateTime | Invalid DateTime has been provided. (TJC-100012) | Highlight the template/EffectiveTime with incorrect date | Only validate effectiveTime, Time, and birthTime in QRDA that are listed in TJC xPath Document but NOT used by current eCQMs. |
100022 | Discharge Date | Critical | No Discharge Date in Reporting Period | CMS Program Name is an Inpatient Program (HQR_PI, HQR_IQR, HQR_PI_IQR) and there is NO Inpatient Discharge Date within the reporting period defined in the Reporting Parameters section in the QRDA file. (TJC-100022) | Highlight the first Inpatient Encounter | When CMS Program Name is an Inpatient Program (HQR_PI, HQR_IQR, HQR_PI_IQR) |
100023 | High@value | Critical | Event start date after the end date | Event End date is before the Event Start Date. (TJC-100023) | Highlight the template/EffectiveTime with incorrect date | Rejection for all dates in TJC xPath Document required by current eCQMs.apply offset before validation |
100024 | High@value | Warning | Event start date after the end date | Event End date is before the Event Start Date. (TJC-100024) | Highlight the template/EffectiveTime with incorrect date | Warning for all dates in TJC xPath Document but not used by current eCQMs.apply offset before validation |
100025 | Encounter ID | Warning | Inconsistent reporting of Inpatient Encounter | CMS Program Name is an Inpatient Program and | Highlight the first instance of Inpatient Encounter template for the same episode | For CMS Program Name is an Inpatient Program (HQR_PI, HQR_IQR, HQR_PI_IQR) |
100026 | Encounter ID | Warning | Duplicate Inpatient Encounter Detected | CMS Program Name is an Inpatient Program and two instances of inpatient encounter template are exactly the same. The last instance in the QRDA file will be used for measure evaluation. Remove duplicate encounter template/s to avoid unexpected outcome. (TJC-100026) | Highlight the first instance of Inpatient Encounter template for the same episode | For CMS Program Name is an Inpatient Program (HQR_PI, HQR_IQR, HQR_PI_IQR) |
100027 | Patient id | Critical | Invalid QRDA XML file | Source Viewer stays blank with no data | Any character which engine is not able to process will trigger this error | |
100029 | Patient id | Critical | Invalid Patient ID | Invalid Patient ID has been provided. (TJC-100029) | Expectation: Highlight the Patient ID | The patient-id fields cannot be greater than 100 characters OR there are invalid characters. |
100031 | XML File | Critical | Invalid QRDA XML file | Source Viewer stays blank with no data | File is not a valid QRDA XML file | |
100032 | CCN | Critical | Incorrect CCN Reported | The CCN does not match with the CCN associated to the current HCO. (TJC-100032) | Highlight the CCN Number | The CCN is provided. However, the CCN in the document does not match with the CCN associated to the current user. |
100035 | Header Effective Time | Critical | Missing or invalid Header EffectiveTime | Invalid or null US Realm Date and Time is provided. (TJC-100035) | Highlight the header effectiveTime | US Realm Date and Time under <header> as given in the XPath is null or invalid. |
100036 | Encounter ID | Warning | Inpatient encounter outside of the reporting quarter | CMS Program Name is an inpatient Program and there exists an inpatient encounter with discharge datetime outside of the reporting quarter defined in the Reporting Parameter of the QRDA document. (TJC-100036) | Highlight the Encounter ID | For CMS Program Name is an Inpatient Program (HQR_PI, HQR_IQR, HQR_PI_IQR) |
100037 | Route Code | Warning | A required Medication Route is missing | Route code is missing for an administered medication, and is required by a reported eCQM. (TJC-100037) | Highlight the Medication Template, which is missing the route, AND has negationInd=false or it's negationInd missing AND the code belongs to the value set required by eCQM | Only trigger the warning for those Medications that belong to the value set that eCQM asks for, AND do not have the route and are not negated with negationID=true. (e.g. VTE-1 and VTE-2)Below listed are Value sets and Codes that need Route code1. Unfractionated Heparin value set (2.16.840.1.113883.3.117.1.7.1.218) contains the following codes:(1361607, 1658717, 1659195, 1659197)2. Low Dose Unfractionated Heparin for VTE Prophylaxis (2.16.840.1.113762.1.4.1045.39 ) value set contains the following codes :(1361226, 1361568, 1361574, 1361577, 1361615, 1361853, 1362831, 1658634, 1658637, 1658647, 1658659, 1659260, 1659263, 1798389, 2121591)RouteCode ValueSets and codes |
100039 | Result Unit | Warning | Unacceptable Unit Reported | There exists an unacceptable unit in the QRDA document. Enter the correct unit as definied in the eCQM logic to avoid an unexpected outcome. (TJC-100039) | Highlight the incorrect/invalid unit | Validate this edit only when below conditions are met-1. When below specified measures are reported2. When code is in the below listed Value Sets3. When result value is providedNote: DO NOT trigger warning if code is provided from below listed Value Sets but reported measure is not from below specified measures.List of measures, required units and data element/Value Sets:1. eHH-1 and eHH-2 - unit- ‘mg/dL’ for Laboratory Test Performed"Laboratory Test, Performed: Glucose Lab Test Mass Per Volume" using "Glucose Lab Test Mass Per Volume (2.16.840.1.113762.1.4.1248.34)"2. ePC-01, ePC-02, ePC-05, ePC-06, ePC-07 - unit- 'wk', 'week' or 'weeks' for Assessment Performed Gestational Age calculation.For ePC-01, ePC-02, and ePC-07"- Assessment, Performed: Estimated Gestational Age at Delivery" using "Estimated Gestational Age at Delivery (2.16.840.1.113762.1.4.1045.26)"For ePC-05 and ePC-06- code "Gestational age--at birth" ("LOINC Code (76516-4)")3. For ePC-05, ePC-06 - 'g' for Assessment Performed Birth Weight calculationvalueset "Birth Weight" (2.16.840.1.113762.1.4.1029.194) |
100041 | Header intendedRecipient | Critical | No outpatient measure reported | CMS Program Name is "HQR_OQR", but there is no TJC supported outpatient measure reported in file. (TJC-100041) | Highlight the CMS program name | This edit triggers when QRDA file contains CMS program name as 'HQR_OQR' but no TJC supported outpatient measures are reported. |
100042 | Header intendedRecipient | Critical | No inpatient measure reported | CMS Program Name is an Inpatient Program (HQR_PI, HQR_IQR, HQR_PI_IQR), but there is no TJC supported inpatient measure reported in file. (TJC- 100042) | Highlight the CMS program name | This edit triggers when QRDA file contains CMS program name as 'HQR_OQR' but no TJC supported outpatient measures are reported. |
100043 | Header intendedRecipient | Warning | Inpatient measure reported for outpatient CMS program name | Inpatient measures will not be evaluated when reported CMS program name is 'HQR_OQR' . (TJC- 100043) | Highlight the CMS program name | This warning will only trigger when*CMS program name as 'HQR_OQR '*QRDA file contains TJC supported outpatient measures*And at least one of the TJC supported inpatient measures |
100044 | Header intendedRecipient | Warning | Outpatient measure reported for inpatient CMS program name | Outpatient measures will not be evaluated when reported CMS program name as ' HQR_PI' OR ''HQR_IQR' OR 'HQR_PI_IQR ' . (TJC- 100044) | Highlight the CMS program name | This warning will only trigger when*CMS program name as 'HQR_PI' OR ''HQR_IQR' OR 'HQR_PI_IQR '*QRDA file contains TJC supported Inpatient measures*And at least one of the TJC supported outpatient measures |
100045 | Departure Date | Critical | No ED Relevant Period High Date in Reporting Period | CMS Program Name is 'HQR_OQR' and there is NO ED Relevant Period High Date (effectiveTime/ high) within the reporting period defined in the Reporting Parameters section in the QRDA file. (TJC-100045) | Highlight the first Departure Encounter | When CMS Program Name is an outpatient Program (HQR_OQR) |
100046 | Encounter ID | Warning | Inconsistent reporting of Outpatient Encounter | CMS Program Name is an Outpatient Program and | Highlight the first instance of Outpatient Encounter template for the same episode | For CMS Program Name is an Outpatient Program (HQR_OQR) |
100047 | Encounter ID | Warning | Duplicate Outpatient Encounter Detected | CMS Program Name is an Outpatient Program and two instances of outpatient encounter template are exactly the same. The last instance in the QRDA file will be used for measure evaluation. Remove duplicate encounter template/s to avoid unexpected outcome. (TJC-100047) | Highlight the first instance of Outpatient Encounter template for the same episode | For CMS Program Name is an Outpatient Program (HQR_OQR) |
100048 | Encounter ID | Warning | Outpatient encounter outside of the reporting quarter | CMS Program Name is an Outpatient Program and there exists an outpatient encounter Relevant Period High Date outside of the reporting quarter defined in the Reporting Parameter of the QRDA document. (TJC-100048) | Highlight the Outpatient Encounter ID | For CMS Program Name is an Outpatient Program (HQR_OQR) |
Schematron Error Messages
Message # | Section / Element | Status | Data Accuracy Label(Short Description) | Source Viewer Description (Long Description) | Expected Behavior in Source Viewer Upon Clicking Error | Additional Information |
CMS_0121 | Time Zone | Critical | r-validate_TZ-errors | A Coordinated Universal Time (UTC time) offset should not be used anywhere in a QRDA Category I file or, if a UTC time offset is needed anywhere, then it must be specified everywhere a time field is provided (CONF: CMS_0121) | Highlights the date time field that has the inconsistent UTC time offset | Validate time zone offset for all datetime fields in the QRDA I file. |
TJC_0121 | Time Zone | Critical | r-validate_TZ-errors | A Coordinated Universal Time (UTC time) offset should not be used anywhere in a QRDA Category I file or, if a UTC time offset is needed anywhere, then it must be specified everywhere a time field is provided (CONF: TJC_0121) | Highlights the date time field that has the inconsistent UTC time offset for an Observation result that is a datetime | Validate time zone offset for all datetime fields in the QRDA I file. |
TJC-0007 | Reporting Parameter | Critical | Reporting-Parameters-Act-TJC-errors | This effectiveTime SHALL contain exactly one [1..1] low and exactly one [1..1] high for reporting period start date and end date respectively. Reporting Period must only represent one calendar quarter with valid start and end dates of the quarter (TJC-0007). | Highlights Reporting Parameter section containing invalid start date and end date | Validates the start and end date of Reporting Period in a given QRDA I file |
TJC-0011 | CCN | Critical | QDM_based_QRDA_TJC-errors | CCN (Facility CMS Certification Number), if present, SHALL be six to ten characters in length (TJC-0011). | Highlights the header section containing the CCN which does not satisfy the length requirement | Validate CCN in a given QRDA I file. |
TJC-0036 | effectiveTime and Time | Warning | r-validate_effectiveTime-TJC-warnings | effectiveTime or time SHALL have either @value or low and high but SHALL NOT have @value and low and high. (TJC-0036) | Highlight the effectiveTime or Time attribute within a template that contains both @value and @low and/or @high | Validates the effectiveTime/Time attribute of all the data elements in a given QRDA I file |
TJC-0048 | Document Level templateID | Warning | r-DOCUMENT-TJC-US-HEADER-warnings | This document SHALL contain exactly one [1..1] US Realm document level templateId @root="2.16.840.1.113883.10.20. |
...
22.1. |
...
1" @extension=" |
...
2015- |
...
08-01". CDA data elements will not be validated properly (TJC-0048). |
...
o Please contact your IT staff or vendor that supplied the software being used to generate the QRDA I documents to correct this error.
...
Highlights the US Realm header section, which has incorrect extension | Validates the extension for the US header template ID in a given QRDA I file | ||
TJC-0049 | Document Level templateID | Warning | r-DOCUMENT-TJC-QRDA-HEADER-warnings |
...
...
This document SHALL contain exactly one [1..1] QRDA Category I Framework document level templateId @root="2.16.840.1.113883.10.20.24.1.1" @extension="2017-08-01". QRDA-I data elements will not be validated properly (TJC-0049). |
...
o Section / Element: Document Level templateID
...
Highlights the QRDA Category I header section, which has incorrect extension | Validates the extension for the QRDA header template ID in a given QRDA I file | |||
TJC-0050 | Document Level templateID | Warning | r-DOCUMENT-TJC-QDM-HEADER-warnings | This document SHALL contain exactly one [1..1] QDM-based QRDA |
...
document level templateId @root="2.16.840.1.113883.10.20.24.1. |
...
2" @extension=" |
...
2021-08-01". |
...
o Please contact your IT staff or vendor that supplied the software being used to generate the QRDA I documents to correct this error.
...
title | r-DOCUMENT-TJC-US-HEADER-warnings (warning) |
---|
· Source Viewer: This document SHALL contain exactly one [1..1] US Realm document level templateId @root="2.16.840.1.113883.10.20.22.1.1" @extension="2015-08-01". CDA data elements will not be validated properly (TJC-0048).
o Section / Element: Document Level templateID
...
QDM data elements will not be validated properly (TJC-0050) | Highlights the QDM based QRDA header section, which has incorrect extension | Validates the extension for the QDM header template ID in a given QRDA I file | ||||
TJC-0051 | Date Time Elements | Critical | r-validate_TZ-errors | A Coordinated Universal Time (UTC time) offset should not be used anywhere in a QRDA Category I file or, if a UTC time offset is needed anywhere, then it must be specified everywhere a time field is provided (CONF: TJC_0051) | Highlights the date time field that has the inconsistent UTC time offset | Added an additional constraint to the existing CMS version, for Assessment Performed data element when Result is submitted as date time. |
TJC-0052 | Race | Warning | r-validate_race-TJC-warnings-abstract | You have provided a raceCode that was not found in ValueSet Race urn:oid:2.16.840.1. |
...
114222. |
...
4. |
...
11. |
...
o Please contact your IT staff or vendor that supplied the software being used to generate the QRDA I documents to correct this error.
Expand | ||
---|---|---|
| ||
· Source Viewer: This effectiveTime SHALL contain exactly one [1..1] low and exactly one [1..1] high for reporting period start date and end date respectively. Reporting Period must only represent one calendar quarter with valid start and end dates within the reporting year (TJC-0007). o Section / Element: Reporting Parameter o The Reporting Period start date must be the first day of a calendar quarter. Valid quarter start dates are: January 1, April 1, July 1 and October 1. o For hospital QRDA I documents, the Reporting Period end date must be the last day of the calendar quarter associated to the start date. Valid quarter end dates are: March 31, June 30, September 30 and December 31. |
...
title | r-validate_effectiveTime-TJC-warnings (warning) |
---|
· Source Viewer: effectiveTime or time SHALL have either @value or low and high but SHALL NOT have @value and low and high. (TJC-0036)
o Section / Element: effectiveTime and time
...
836. (TJC-0052) | Highlights the patient section containing the an invalid raceCode | Validates the code in the raceCode template in the patient section in a given QRDA I file | ||||
TJC-0053 | Ethnicity | Warning | r-validate_ethnicity-TJC-warnings-abstract | You have provided a ethnicGroupCode that was not found in ValueSet Ethnicity urn:oid:2.16.840.1.114222.4.11.837. (TJC-0053) | Highlights the patient section containing the an invalid ethnicGroupCode | Validates the code in the ethnicGroupCode template in the patient section in a given QRDA I file |
TJC-0054 | Gender | Warning | r-validate_gender-TJC-warnings-abstract | You have provided a administrativeGenderCode that was not found in ValueSet ONC Administrative Sex urn:oid:2.16.840.1.113762.1.4.1. (TJC-0054) | Highlights the patient section containing the an invalid administrativeGenderCode | Validates the code in the administrativeGenderCode template in the patient section in a given QRDA I file |