The Joint Commission

[HAP Small] Acute Care Hospitals (2025)


CY2025 ORYX Requirements for [HAP Small] Acute Care Hospitals


How are [HAP Small] Acute Care Hospitals defined as it relates to ORYX Requirements?

For The Joint Commission, ORYX performance measurement requirements are specifically applicable to organizations accredited under the Hospital Accreditation Program (HAP).

HAP Small are defined as <26 Licensed beds AND <50,000 Outpatient visits

Refer to your Joint Commission Connect Site eAPP Hospital Volume or view the DDSP HCO Characteristics Organization Requirements tab for licensed bed / outpatient volume information.

See also: DDSP General: Verifying Data Submission & ORYX Requirements DDSP General: Verifying Data Submission & ORYX Requirements


REMINDER: In addition to ORYX performance measurement data submission to The Joint Commission via the Direct Data Submission Platform, effective July 1, 2024, acute care hospitals who are required through a CMS program to participate in NHSN are also required to join The Joint Commission NHSN Group. Participation in this group gives Joint Commission access to the following measures with no patient identifiers: CAUTI, CLABSI, CDI, MRSA Bacteremia, SSI: Colon, SSI: Hyst.

See Also: 12. NHSN Group for The Joint Commission 12. NHSN Group for The Joint Commission

 


  • eCQMs and Chart-abstracted measures are submitted for all four (4) quarters unless otherwise noted.

  • HAP Small Acute Care Hospitals are not required to submit PC measures but may do so if they choose if obstetrical services are provided.

  • In order to meet ORYX requirements, submitted measures must be applicable to patient population/services offered.

HAP Small] Hospitals with <26 Licensed beds AND < 50,000 Outpatient visits

HAP Small] Hospitals with <26 Licensed beds AND < 50,000 Outpatient visits

REQUIRED: Submit a minimum of one (1) eCQM plus two additional measures (chart-abstracted measures and/or eCQMs) applicable to patient population/ services offered.

  • May elect to submit additional measures based on patient population / services offered.

  • Not required to submit PC measures but may do so if they choose.

REQUIRED: Your hospital must submit a minimum of one (1) eCQM applicable to patient population/services from those listed below:

IP-ExRad (eCQM) Excessive Radiation Dose or Inadequate Image Quality for Diagnostic Computed Tomography (CT) in Adults (Inpatient) (NEW)

OP-ExRad (eCQM) Excessive Radiation Dose or Inadequate Image Quality for Diagnostic Computed Tomography (CT) in Adults (Outpatient) (NEW)

NOTE: If OP-ExRad is reported, one (1) self-selected quarter is required and will count as a complete measure / towards meeting the eCQM requirement

HH-PI (eCQM) Hospital Harm - Pressure Injury (NEW)

GMCS (eCQM) Global Malnutrition Composite Score

HH-HYPO (eCQM) Hospital Harm—Severe Hypoglycemia Measure

HH-HYPER (eCQM) Hospital Harm—Severe Hyperglycemia Measure

HH-ORAE (eCQM) Hospital Harm—Opioid Related Adverse Events

OP-40 (eCQM) ST-Segment Elevation Myocardial Infarction (STEMI)

NOTE: If OP-40 is reported, two (2) self-selected quarter are required and will count as a complete measure / towards meeting the eCQM requirement.

PC-01 (eCQM) Elective Delivery

PC-05 (eCQM) Exclusive Human Milk Feeding

PC-06 (eCQM) Unexpected Complications in Term Newborns

PC-07 (eCQM) Severe Obstetric Complications

Safe Use of Opioids (eCQM) Safe Use of Opioids - Concurrent Prescribing

STK-2 (eCQM) Discharged on Antithrombotic Therapy

STK-3 (eCQM) Anticoagulation Therapy Atrial Fibrillation/Flutter

STK-5 (eCQM) Antithrombotic Therapy by End of Hospital Day 2

VTE-1 (eCQM) Venous Thromboembolism Prophylaxis

VTE-2 (eCQM) ICU Venous Thromboembolism Prophylaxis

OPTIONAL Chart-abstracted measures (CAM); hospitals may elected to submit any of the below measures if they choose. NOTE: Any chart-abstracted measure(s) submitted the first quarter of the calendar year are required to be submitted for the remainder of the calendar year unless otherwise noted.

ED-1 (CAM) Median ED Arrival to ED Departure-Admit

ED-2 (CAM) Admit Decision Time to ED Departure-Admit

HBIPS-2 (CAM) Hours of Physical Restraint Use

HBIPS-3 (CAM) Hours of Seclusion Use

IMM-2 (CAM) Influenza Immunization

NOTE: IMM-2 is a seasonal measure; only 1Q and 4Q data are submitted

OP-18 (CAM) Median ED Arrival-ED Departure at Discharge

OP-23 (CAM) Head CT or MRI Scan Results-Stroke

PC-01 (CAM) Elective Delivery

PC-02 (CAM) Cesarean Birth

PC-05 (CAM) Exclusive Human Milk Feeding

PC-06 (CAM) Unexpected Complications in Term Newborns

SDOH-1 (CAM) Screening for Social Drivers of Health

NOTE: SDOH measures are not submitted quarterly, but are instead submitted annually in alignment with the 4Q CAM submission deadline.

SDOH-2 (CAM) Screen Positive Rate for Social Drivers of Health

NOTE: SDOH measures are not submitted quarterly, but are instead submitted annually in alignment with the 4Q CAM submission deadline.

SUB-2 (CAM) Alcohol Use Brief Intervention

SUB-3 (CAM) Alcohol & Drug Use Treatment at Discharge

TOB-3 (CAM) Tobacco Use Treatment at Discharge


See also: ORYX FAQs Measure Requirements: By Organization Type: 5. Measure Requirements: By Organization Type

Return to: ORYX Performance Measurement Reporting Requirements Main Page:
https://jointcommission-ddsp.atlassian.net/wiki/spaces/DCS/pages/403472385

©The Joint Commission, All Rights Reserved
The Joint Commission is a registered trademark of The Joint Commission.